{"product_id":"hm-digital-sm-1-single-inline-tds-meter","title":"HM Digital SM-1 Single Inline TDS Meter – RO \u0026 DI Water Monitor","description":"\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eHM Digital SM-1 Single Inline TDS Meter\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e provides a simple, permanent way to monitor the TDS level of a single water line.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIt is particularly useful for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eReverse Osmosis (RO) and deionisation (DI) systems\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, allowing you to check the TDS of the filtered product water at the press of a button without collecting a water sample or using a handheld meter.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe SM-1 installs directly into \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1\/4\" tubing\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e using the supplied quick-connect T-fitting and provides an easy-to-read digital TDS measurement whenever required.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eIdeal for Monitoring RO Product Water\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe SM-1 is normally installed on the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efiltered water outlet of an RO system\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eOnce installed, simply press the power button to see the current TDS reading of the water passing through the line.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eMonitoring this reading over time can help identify changes in RO or DI system performance.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFor example, if your RO water normally measures around \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e10 ppm\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e but gradually increases to 20, 30 or 40 ppm under similar feed-water conditions, this may indicate that the membrane's performance should be investigated.\u003c\/span\u003e\u003c\/p\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWant to measure both incoming and filtered water?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eConsider the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eHM Digital DM-1 Dual Inline TDS Meter\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, which monitors both feed and product water and makes calculating RO membrane rejection much easier.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch3\u003e\u003cspan\u003eFeatures\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003ePermanently installed \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003einline TDS monitor\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eMeasures TDS from \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eone water line\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIdeal for RO and DI product-water monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEasy-to-read digital display\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eMeasurement range up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e9990 ppm\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003e±2% accuracy\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAutomatic Temperature Compensation (ATC)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eFactory calibrated at \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e342 ppm NaCl\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCan be recalibrated if required\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAutomatic shut-off after approximately 10 minutes\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBattery powered – no mains power required\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eIncludes \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1\/4\" quick-connect T-fitting\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCompact and easy to install\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eHM Digital states that the SM-1 is supplied with one 1\/4\" T-fitting and is factory calibrated using a 342 ppm NaCl solution. \u003c\/span\u003e\u003cspan\u003e\u003ca href=\"https:\/\/hmdigital.com\/sm-1\/?utm_source=chatgpt.com\"\u003ehmdigital.com\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eSpecifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eHM Digital SM-1\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSM-1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eType\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSingle Inline TDS Monitor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eTDS Range\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0–9990 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eResolution 0–999 ppm\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eResolution 1000–9990 ppm\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±2%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eTemperature Compensation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAutomatic (ATC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eCalibration\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAdjustable \/ factory calibrated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eFactory Calibration\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e342 ppm NaCl\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eNumber of Sensors\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eConnection\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1\/4\" quick-connect T-fitting\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eSensor Cable Length\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 62.2 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003ePower\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 × LR44 batteries\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eAuto Shut-Off\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 10 minutes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e76 × 20 × 47 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 79 g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cspan\u003eSpecifications are consistent with HM Digital's current product catalogue. \u003c\/span\u003e\u003cspan\u003e\u003ca href=\"https:\/\/hmdigital.com\/wp-content\/uploads\/2025\/11\/251013-2-2026-CATA-%EB%AF%B8%EA%B5%AD%EC%A0%84%EC%9A%A9-VER1.0E.US-COMP.pdf?utm_source=chatgpt.com\"\u003ehmdigital.com\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eSuitable For\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eReverse Osmosis systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRO\/DI systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDeionised water systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDrinking water RO systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAquarium RO\/DI systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHydroponics\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eWater purification equipment\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eWater coolers and dispensers\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eEasy Installation\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe supplied sensor fitting installs directly into a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1\/4\" water line\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFor an RO system, we generally recommend installing the SM-1 on the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eRO product-water line after the membrane\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eOnce installed:\u003c\/span\u003e\u003c\/p\u003e\n\u003col start=\"1\"\u003e\n\u003cli\u003e\n\u003cspan\u003ePress the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eON\/OFF\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e button.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAllow the reading to stabilise.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRead the TDS directly from the digital display.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eThe meter automatically switches off after approximately 10 minutes to conserve battery life.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cspan\u003eHM Digital also notes that the sensor can be installed in different positions depending on the application, although filtered\/product water is the typical installation point. \u003c\/span\u003e\u003cspan\u003e\u003ca href=\"https:\/\/device.report\/manual\/19729882?utm_source=chatgpt.com\"\u003eDevice Report\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eWhat Does TDS Mean?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eTDS – Total Dissolved Solids\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – is a measurement of dissolved ionic material in water and is displayed in \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eparts per million (ppm)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAn RO membrane removes a large proportion of these dissolved substances, so monitoring product-water TDS provides a useful indication of changes in membrane performance.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eImportant\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eA TDS meter does \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003enot identify individual contaminants\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and does not determine whether water is microbiologically safe.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIt is also important to understand that conventional sediment and activated carbon filters may remove contaminants \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ewithout significantly changing TDS\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. The SM-1 is therefore particularly useful for monitoring technologies such as \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eReverse Osmosis and deionisation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, where changes in dissolved solids are relevant.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eWhat's Included\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003eHM Digital SM-1 Single Inline TDS Monitor\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e1 × inline TDS sensor\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e1 × \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1\/4\" quick-connect T-fitting\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBatteries\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOperating instructions\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003e\u003cspan\u003eSM-1 vs DM-1\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003e\u003cspan\u003eSM-1\u003c\/span\u003e\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003e\u003cspan\u003eDM-1\u003c\/span\u003e\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMeasurement Points\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct-water TDS\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFeed-water TDS\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOptional installation point\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCompare IN vs OUT\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e—\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCalculate RO rejection easily\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e—\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e1\/4\" Sensors\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eChoose the SM-1\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e if you simply want to monitor one water line.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eChoose the DM-1\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e if you want to compare the feed water and RO product water from the same permanently installed meter.\u003c\/span\u003e\u003c\/p\u003e","brand":"HM Digital","offers":[{"title":"Default Title","offer_id":48472169382025,"sku":"SM-1","price":69.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0584\/7633\/1145\/files\/SM-1.png?v=1790821903","url":"https:\/\/www.waterfiltersonline.co.nz\/products\/hm-digital-sm-1-single-inline-tds-meter","provider":"Water Filters Online Aotearoa","version":"1.0","type":"link"}