Annual Maintenance Kit for Puretec Hybrid G8, R3 & WU-UV100 UV Systems
Everything you need to service your Puretec Hybrid G8, R3 or WU-UV100 UV system in one convenient kit. Annual replacement is essential to maintain full disinfection performance.
Compatibility
| Compatible System | Maintenance Kit Reference |
|---|---|
| Puretec Hybrid G8 | HR-G8R3 |
| Puretec Hybrid R3 | HR-G8R3 |
| Puretec WU-UV100 | HR-G8R3 |
What's Included in This Kit
- Puretec RL6 Compatible UV Lamp – L-520-46-4E (replaces Puretec RL6)
- 20 micron Pleated Filter 10" Jumbo – 10JPL20 (replaces Puretec PL20MP1)
- 1 micron Sediment Depth Filter 10" Jumbo – SDC-45-1001 (replaces Puretec PX01MP1)
Why Replace Annually?
UV lamps lose disinfection effectiveness after 12 months of operation — even if they still appear to glow. Filters accumulate sediment and contaminants, reducing flow and water quality. Annual servicing keeps your system performing to its rated specification.
Important: Resetting the Ballast
After replacing the lamp, follow the instructions in your System Service Manual to reset the 365-day countdown ballast back to 365. This ensures your system accurately tracks the next service interval.
How to Service Your System
- Turn off power and water supply to the system
- Allow the lamp to cool for at least 5 minutes
- Replace the UV lamp — avoid touching the glass with bare hands
- Replace both filter cartridges in order
- Restore water supply and check for leaks
- Power on and reset the 365-day ballast countdown
Matching UV Lamp
Also need a replacement UV lamp only? See our replacement lamps collection for compatible options.
Local NZ Stock | Fast Shipping | NZ Customer Support